Home About us Editorial board Search Ahead of print Current issue Archives Submit article Instructions Subscribe Contacts Login 
  • Users Online: 257
  • Home
  • Print this page
  • Email this page
ORIGINAL ARTICLE
Year : 2020  |  Volume : 6  |  Issue : 1  |  Page : 24-31

Magnetic resonance imaging-guided focused ultrasound robotic system with the subject placed in the prone position


1 Department of Electrical Engineering, Cyprus University of Technology, Limassol, Cyprus
2 Department of R and D, Medsonic Ltd., Limassol, Cyprus
3 Medical Physics Division, Nicosia General Hospital, Nicosia, Cyprus
4 Department of Radiology, Ygia Polyclinic, Limassol, Cyprus

Correspondence Address:
Christakis Damianou
Department of Electrical Engineering, Cyprus University of Technology, 30 Archbishop Kyprianou Street, 3036 Limassol
Cyprus
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/digm.digm_2_20

Rights and Permissions

Background: In this article, a medical robotic system that performs magnetic resonance imaging-guided focused ultrasound surgery ablation is presented. The main innovation of this robotic system is that all the actuators are placed outside the water container. The transducer is immersed in water through an arm which is attached to the angular stage. Materials and Methods: The system includes three linear and one angular stage. The device uses piezoelectric motors for each motion stage. The accuracy was achieved with optical encoders. A focused transducer operated at 1 MHz with a radius of curvature of 10 cm and a diameter of 4 cm was used. A polyacrylamide gel was used to assess the ultrasound protocol. Results: The system was tested in the magnetic resonance imaging (MRI) environment and was proved to be a magnetic resonance compatible. The accuracy of the system was tested, and it was found that spatial steps of 0.2 mm can be safely and reliably achieved. With this robotic system, it is possible to access many organs that ultrasound penetrates with the patient placed in a prone position. Conclusion: The proposed robotic system can be modified so that it can be used for other applications. One example of an alternative application is MRI-guided biopsy. Another application is to replace the transducer arm with a radio frequency (RF) device to perform MRI guided RF ablation. Finally, the maneuverability of the robotic system can be enhanced further by attaching another angular stage to the system.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed107    
    Printed6    
    Emailed0    
    PDF Downloaded16    
    Comments [Add]    

Recommend this journal